Functional Comparison
The table below reflects the features of ReticMaster compared to other generic products. The comparisons with the power flow tools are mostly focused on areas where ReticMaster specialises. Some power flow tools may exhibit some features not mentioned or may have capabilities that are not reflected as such.
|
ReticMaster |
Radial Power Flow |
Meshed Power Flow |
|
| Generator Modelling |
|
|
|
| Generator source impedance models |
ü |
ü |
ü |
| Multiple generation positions |
ü |
Seldom |
ü |
| Interconnected generators |
û |
û |
ü |
| Transformer Modelling |
|
|
|
| Two winding transformers |
ü |
ü |
ü |
| Three winding transformers |
ü |
ü |
ü |
| 3 phase primary / 3 phase secondary |
ü |
ü |
ü |
| 2 phase primary / 1 phase secondary |
ü |
Limited |
û |
| 2 phase primary / dual phase secondary |
ü |
û |
û |
| Automatic tap change |
ü |
ü |
ü |
| Transformer grounding |
ü |
ü |
ü |
| Line Drop Compensation |
ü |
Few |
Varies |
|
Grounding and NEC/R modelling for unbalanced fault calculations. |
ü |
Few |
Few |
| Branch Modelling |
|
|
|
| Resistance, reactance and capacitance in positive & zero sequence |
ü |
ü |
ü |
| Load Modelling |
|
|
|
| Residential household consumers |
ü |
û |
û |
| Stochastic loads |
ü |
û |
û |
| 3 phase bulk loads |
ü |
ü |
ü |
| 2 phase bulk loads (ungrounded) |
ü |
ü |
û |
| 1 phase bulk loads |
ü |
ü |
û |
| Dual phase bulk loads (180° Phase Displacement) |
ü |
û |
û |
| Multiple simultaneous load scaling functionality |
ü |
Limited |
Limited |
| Residential load scaling ability |
ü |
û |
û |
| Series / Shunt capacitor and reactor |
ü |
ü |
ü |
| Analysis Functionality |
|
|
|
| Automatic single line diagram generation |
ü |
û |
û |
| Automatic conductor optimisation & selection (sizing) |
ü |
û |
û |
| Point & Click multiple conductor changes |
ü |
û |
û |
| Motor starting simulation |
ü |
ü |
ü |
| Automatic fault current calculation at every node |
ü |
û |
û |
| Node structure coding and costing models |
ü |
û |
û |
| Unlimited number of nodes (computer dependant) |
ü |
Varies |
Varies |
| Schematic network representation & modelling |
ü |
Varies |
Varies |
| Geographic network representation & modelling |
ü |
û |
û |
| Detailed per phase voltage profile results |
ü |
Limited |
Limited |
| Automatic and continuous calculations |
ü |
û |
û |
| Interconnected power flow |
Limited |
Limited |
ü |
|
System stability & Harmonic current analysis |
û |
Limited |
ü |
| Automatic residential phase balancing |
ü |
û |
û |
| Multiple node placement |
ü |
û |
û |
| Powerful automatic network changing interface |
ü |
û |
û |
| Demand Side / Energy Management |
ü |
û |
û |
| Data Integrity Checking |
ü |
û |
Few |
| Problem Reporting |
ü |
û |
û |
| User Defined Reporting |
ü |
û |
Few |